Station Pikermi

Station Details: The characteristics of the station.
Instruments: A list of instruments installed in this station. Click on an instrument name for further information.
Timeseries: A list of historical timeseries of specific variables measured by sensors installed on this station. Click on a timeseries name for further information.
Charts: A number of hydrometeorological charts with near real time data of this station.

 

Station Details

ID 16
Name Pikermi
Short Name Pikermi
Remarks The station is sited within premises of the Center for Renewable Energy Resources in Pikermi (ground altitude 133 m). The station is active since 21/12/2005.
Water Basin
Water Division
Political Division Greece
Abscissa 493583.15
Ordinate 4205666.35
SRID 2100
Approximate False
Altitude 133.00
ASRID None
Owner National Technical University of Athens
Type Meteorological
Is Active True
Is Automatic True
Start Date
End Date
Creator Unknown
Overseers
George Papoutsoglou
Instruments
ID Name Type Manufacturer Model Is Active Start Date End Date
95 Air humidity sensor Humidity sensor Rotronic MP101A True
94 Air temperature sensor Air temperature sensor Rotronic MP101A True
101 Battery indicator Battery sensor True
159 Evaporation sensor Evaporation sensor Scientific Enterprises Ltd EVS-01 True
99 Net radiation sensor Solar radiation sensor Kipp and Zonen NR-LITE True
92 Rainfall sensor 1 Rainfall sensor Environmental Measurements Ltd. - Campbell Sc. ARG-100 True
93 Rainfall sensor 2 Rainfall sensor R M Young - Campbell Scientific, Inc. 52202 True
136 Soil Moisture Sensor Water content reflectometer Campbell Scientific, Inc. CS616-L True
98 Solar radiation sensor Solar radiation sensor Kipp and Zonen SP-LITE True
100 Sunshine duration sensor Sunshine duration sensor Kipp and Zonen CSD-1 True

More...

Timeseries
ID Name Variable Time step Unit Of Measurement Instrument Start Date End Date
720 Pik_solrad_irr Solar radiation 10-minute - 10 minute(s) W/m2 Solar radiation sensor 2005/12/21 00:10 2017/09/01 12:00
859 Pik_airtemp_irr Temperature 10-minute - 10 minute(s) deg C Air temperature sensor 2005/12/21 00:10 2017/09/01 12:00
1015 Daily Precipitation Rainfall Daily - 1 day(s) mm None 2005/12/22 00:00 2017/06/14 00:00
712 Pik_airtempmax_irr Temperature 10-minute - 10 minute(s) deg C Air temperature sensor 2005/12/21 00:10 2017/09/01 12:00
905 Pik_soil_humidity_raw Soil moisture 10-minute - 10 minute(s) % Soil Moisture Sensor 2009/03/12 10:20 2017/09/01 12:00
906 Pik_evap_pan_raw Stage (Evaporation pan) 10-minute - 10 minute(s) mm Evaporation sensor 2009/03/12 10:20 2017/09/01 12:00
1035 Annual Precipitation Rainfall Annual - 1 year(s) mm None 2006/01/01 00:00 2016/01/01 00:00
918 Pik_evaporation Pan evaporation 10-minute - 10 minute(s) mm None 2009/03/12 10:30 2011/05/30 08:10
718 Pik_rain1_irr Rainfall 10-minute - 10 minute(s) mm Rainfall sensor 1 2005/12/21 00:10 2017/09/01 12:00
713 Pik_airtempmin_irr Temperature 10-minute - 10 minute(s) deg C Air temperature sensor 2005/12/21 00:10 2017/09/01 12:00

More...

Station (Gentity) Alternative Codes No data available
Station (Gentity) Files No data available
Station (Gentity) Generic data No data available
Station (Gentity) Events
ID Date Type User Report
282 2014/10/17 Maintenance dpanag From 2014/10/17 12:20 to 2014/10/23 11:50 temperature and relative humidity sensors out of order due to maintenance reasons
260 2013/03/05 Maintenance giopap From 2013-03-05 12:30 to 2013-03-05 12:30, Rainfall sensors 1 and 2 (TS ID:1195, 1196), Maintenance Procedures - Values should be zero
258 2013/02/11 Maintenance giopap From 2013-02-11 12:00 to 2013-02-11 12:10, Rainfall sensors 1 and 2 (TS ID:1195, 1196), Maintenance Procedures - Values should be zero
235 2012/11/29 Maintenance giopap From 2012-11-29 10:10 to 2012-11-29 10:10, Rainfall sensors 1 and 2 (TS ID:1195, 1196), Maintenance Procedures - Values should be zero
189 2012/10/02 Maintenance giopap From 2012-10-02 10:40 to 2012-10-02 10:40, Rainfall sensor 1 (TS ID:1195), Maintenance Procedures - Values should be zero
188 2012/08/30 Maintenance giopap From 2012-08-30 10:00 to 2012-08-30 10:10, Rainfall sensors 1 and 2 (TS ID:1195, 1196), Maintenance Procedures - Values should be zero
57 2012/05/11 Maintenance giopap From 2012-05-11 09:10 to 2012-05-11 10:00, Rainfall sensors 1 and 2 (TS ID:1195, 1196), Maintenance Procedures - Values should be zero
190 2012/05/11 Maintenance giopap From 2012-05-11 09:00 to 2012-06-22 09:00, Evaporation pan - stage sensor - (TS ID:1201), has been left empty for maintenance purposes
56 2012/03/21 Maintenance giopap From 2012-03-21 12:20 to 2012-03-21 12:30, Rainfall sensors 1 and 2 (TS ID:1195, 1196), Maintenance Procedures - Values should be zero
34 2012/01/25 Maintenance giopap From 2012-01-25 11:20 to 2012-01-25 11:20, Rainfall sensors 1 and 2 (TS ID:1195, 1196), Maintenance Procedures - Values should be zero

More...